Vendor: More Brands
MTL4031 Vibration Transducer Interface | Eaton MTL
Product Introduction The MTL4031 safely interfaces vibration sensors in hazardous areas with monitoring systems. It supports 3-wire eddy probes and high-frequency accelerometers for rotating machinery diagnostics. Key Features Single-channel interface for Zone 0/Div. 1 hazardous areas Wide signal range: −20V to −0.5V with ±100mV... -
Vendor: More Brands
MTL4041B Power Supply Module Eaton MTL
Product Overview The MTL4041B is a precision signal repeater and power supply for hazardous area transmitters. It supports both conventional 4-20mA and smart transmitters with HART communication capabilities, providing safe-area signal conditioning with excellent accuracy. Key Features Supports 2/3-wire 4-20mA transmitters in Zone 0/Div.1... -
Vendor: More Brands
MTL4045C MTL - Temperature Transmitter
Product Introduction The MTL4045C safely repeats 4-20mA signals in hazardous areas. This isolator drives I/P converters or loads up to 800Ω with 16V output capability. Its floating input/output circuits ensure reliable operation in Zone 0/Div.1 locations. Key Features Single-channel 4-20mA signal repeater for hazardous... -
Vendor: More Brands
MTL4073 Hazardous Area Temperature Transmitter
MTL4073 Hazardous Area Temperature Transmitter Precision temperature monitoring for explosive environments just got smarter. The MTL4073 transforms thermocouple and RTD signals into rock-solid 4-20mA outputs, engineered for mission-critical industrial applications. Why Professionals Choose MTL4073 ✔ 8 thermocouple types supported ✔ Platinum RTD compatibility ✔... -
Vendor: More Brands
MTL4511 Eaton MTL - Switch/ Proximity Detector Interface
MTL4511 Hazardous Area Switch Interface with Fault Detection Safety Certifications Protection Level Standard Hazardous Area Zone 0, IIC, T6 / Div. 1, Group A Proximity Detection BS EN60947-5-6:2001 (NAMUR) Switching Characteristics Parameter Value Input Thresholds ON: >2.1mA (<2kΩ), OFF: <1.2mA (>10kΩ) Hysteresis 200μA (650Ω... -
Vendor: More Brands
MTL4516 Hazardous-Area Switch Interface Eaton MTL
MTL4516 Dual-Channel Hazardous-Area Switch Interface Key Features Controls two safe-area loads from hazardous-area switches or proximity sensors. Built-in Line Fault Detection (LFD) with LED alarms. Supports NAMUR sensors and contact inputs. Technical Specifications Channels: 2 (independent) Input Voltage: 7-9V DC (1kΩ ±10%) Trigger Threshold:... -
Vendor: More Brands
MTL4541 | MTL - Repeater Power Supply
MTL4541 Hazardous Area 4-20mA Isolator with HART Communication Key Features HART Support Bi-directional communication Certification Zone 0, IIC, T4-T6 / Div. 1, Group A Transmitter Power 16.5V @ 20mA output Technical Specifications Parameter Value Input Range 0-24mA (including over-range) Output Range 4-20mA (0-24mA under/over-range)... -
Vendor: More Brands
MTL4541B MTL Instrument - Repeater Power Supply
Hazardous Area Signal Isolator with HART Support The MTL4541B safely powers 2/3-wire transmitters in explosive areas while repeating 4-20mA signals to safe zones. This intrinsically safe barrier maintains HART communication for smart instrumentation. Core Capabilities Powers Zone 0/Div.1 transmitters with 16.5V@20mA Bi-directional HART signal... -
Vendor: More Brands
MTL4544 | Dual-Channel HART Transmitter Isolator
MTL4544 Dual-Channel HART Transmitter Isolator Dual-Channel Signal Conditioning for Hazardous Areas The MTL4544 provides two independent isolation channels for 2-wire or 3-wire 4-20mA/HART transmitters in Zone 0/Div. 1 hazardous locations. This intrinsically safe solution delivers 16.5V transmitter power while maintaining full HART communication capability.... -
Vendor: More Brands
MTL4544S MTL Instrument | Repeater Power Supply
Dual-Channel Current Sink for Hazardous Areas The MTL4544S provides two independent current sink channels for 4-wire transmitters in explosive environments. This intrinsically safe interface supports 24V sources while maintaining Zone 0 safety standards. Key Advantages Dual-channel design for multi-point monitoring 600Ω current sink capacity... -
Vendor: More Brands
MTL4549 Intrinsically Safe Isolators Eaton MTL
Technical Specifications Channels: Two isolated 4–20mA inputs Hazardous Area Certification: Zone 0, IIC, T4–6 / Div. 1, Group A Load Capacity: 90Ω (min), 800Ω (max at 16V) HART Support: 500Hz–10kHz digital signal bandwidth Accuracy: ±20µA at 20°C, <1.0µA/°C drift Fault Detection: Open/short circuits trigger... -
Vendor: More Brands
MTL4549C | Dual-Channel 4-20mA HART Signal Converter
MTL4549 Dual-Channel 4-20mA HART Signal Converter Dual-Channel Hazardous Area Solution Converts 4-20mA signals to safely control HART devices in Zone 0/Div.1 hazardous locations. Two isolated channels support simultaneous operation of valve positioners, I/P converters, or other field instruments. Key Specifications Channels: 2 fully isolated... -
Vendor: More Brands
MTL4549Y MTL Isolating Driver | Signal Converter
MTL4549 Dual-Channel 4-20mA HART Signal Converter Core Specifications • Channels: 2 isolated 4-20mA paths• HART Support: 500Hz-10kHz bidirectional• Load Capacity: 800Ω per channel (16V @ 20mA)• Accuracy: ±20µA @ 20°C (±1µA/°C drift)• Fault Detection: Open/short-circuit (MTL4549Y = open-only) Performance Highlights • Response Time: 100ms... -
Vendor: More Brands
MTL4573 | Temperature Signal Converter MTL 4500
MTL4573 Temperature Signal Converter Supported Inputs and Minimum SpanThermocouples (THC): J, K, T, E, R, S, B, N (to BS EN 60584-1:1996) — 3mV min. spanGOST XK: GOST P8.585-2001 — -75mV to +75mVRTDs: Pt100, Pt500, Pt1000 (BS EN 60751:2008); Cu-50, Cu-53 (GOST 6651-94); Ni100,... -
Vendor: More Brands
MTL4581 MTL Hazardous Area mV Signal Isolator
MTL4581 Hazardous Area mV Signal Isolator Core Functionality Isolates low-level DC signals (0-50mV) from hazardous areas • Thermocouple burnout protection • Selectable upscale/downscale operation Technical Specifications Input Range: 0 to ±50mV (±55mV overrange) Accuracy: ±0.05% or 5μV Response Time: 150μs to 10% Temp Drift:... -
Vendor: More Brands
MTL4706 Protected Barrier | Eaton MTL
Key Features ✔ Dual-Channel Isolation Independently powers two 2-wire transmitters Negative output voltage (earth-referenced) ✔ Unmatched Accuracy ±2µA precision across all operating conditions Stable 16V minimum at 20mA transmitter supply ✔ Robust Protection Built-in overvoltage safeguards Certified for Zone 0/IIC & Div.1 Groups A/B ✔ Flexible Powering 20–35V... -
Vendor: More Brands
MTL5014 | Dual Relay Hazardous Area Interface
MTL5014 Dual Relay Hazardous Area Interface Critical Safety Ratings Zone 0, IIC, T6 Certified - Highest hazardous area protection Div. 1, Group A Compliant - For explosive atmospheres 250V AC Contact Rating - Handles industrial power loads Technical Performance Relay Response: 10ms maximum switching... -
Vendor: More Brands
MTL5017 Proximity Detector - MTL Instruments
Product Introduction The MTL5017 barrier safely controls two hazardous-area devices from safe-area relays. This intelligent interface connects Zone 0/Division 1 sensors to control systems with advanced diagnostics. Technical Specifications Dual-channel design for simultaneous operation Accepts NAMUR/DIN 19234 proximity detectors Works with switches in Zone... -
Vendor: More Brands
MTL5021 Safe-to-Hazardous Area Control Interface
MTL5021 Safe-to-Hazardous Area Control Interface Explosion Protection Zone 0, IIC, T4-T6 Certified - For gas group IIC environments Div. 1, Group A Rated - Meets NFPA 70 (NEC) requirements 250V Isolation Voltage - Full circuit separation Power Specifications Output Range: 12.85V (min) to 24V... -
Vendor: More Brands
MTL5022 | Eaton MTL Solenoid/Alarm Driver
MTL5022 Hazardous Area Control Interface Core Technical Specifications Output voltage range: 12.9V to 24V Max output current: 60mA Input voltage: 20V–35V DC Load resistance: Up to 133Ω Power dissipation: 1.5W (24V), 2.1W (35V) Isolation: 250V rms/dc (Um) Response time: <100ms Industrial Uses Safe control...