Vai direttamente ai contenuti
Migliaia di Parti di Automazione OEM Disponibili in Magazzino
Consegna Globale Veloce con Logistica Affidabile
Passa alle informazioni sul prodotto
1 su 3

Honeywell 48VDC Safe Output Module FS-SDO-0448

Ordini all'ingrosso e spedizione veloce

Sconto immediato del 10% su EMI e carte di credito/debito Winter Banks

Spedizione Veloce e Affidabile in Tutto il Mondo – Pronta per la Spedizione da Magazzino

Solo 10 unità rimaste
  • Spedizione rapida
  • Politica di reso
  • Prezzo più basso
  • Centro assistenza 24/7

Informazioni sul prodotto

Honeywell FS-SDO-0448 Safe Digital Output Module

The Honeywell FS-SDO-0448 is a high-integrity digital output module engineered for safety-critical control systems. Featuring 4 independent channels with 48VDC switching capability, this module delivers reliable power control while maintaining the stringent requirements of safety instrumented systems.

Core Specifications

  • Brand: Honeywell
  • Model: FS-SDO-0448
  • Product Type: Safe Digital Output Module
  • Number of Channels: 4 Channels
  • Output Voltage: 48 VDC maximum
  • Output Current: 0.75 A per channel continuous
  • Safety Certification: SIL 3 (IEC 61508)

Electrical Performance

  • Output Switching Type: Protected MOSFET solid-state output
  • On-State Resistance: ≤ 0.25 Ω at 25°C
  • Maximum Power Dissipation: 1.8 W per channel
  • Leakage Current: < 50 μA at 48VDC (off-state)
  • Short-Circuit Protection: Electronic current limiting, auto-recovery
  • Switching Frequency: Up to 100 Hz maximum

Timing Characteristics

  • Turn-On Delay Time: ≤ 1.5 ms (command to 90% output)
  • Turn-Off Delay Time: ≤ 1.0 ms (command to 10% output)
  • Diagnostic Test Interval: Configurable from 10 ms to 10 s
  • Fault Detection Time: < 50 ms for short-circuit conditions

Safety Architecture

  • Hardware Fault Tolerance (HFT): 1
  • Safety Integrity Level: SIL 3 (IEC 61508), PLe (ISO 13849-1)
  • Diagnostic Coverage: > 99% (per IEC 61508 requirements)
  • PFH (Probability of Dangerous Failure per Hour): < 1×10⁻⁸
  • Architecture: Dual-path with continuous cross-monitoring

Diagnostic Capabilities

  • Channel Diagnostics: Open-load detection, short-to-ground detection, overtemperature monitoring
  • Internal Diagnostics: Supply voltage monitoring, watchdog timer, memory checksum
  • Status Indication: Per-channel dual-color LEDs (green/red)
  • Remote Diagnostics: Fault reporting via safety bus
  • Test Functions: Programmable pulse test for fault detection

Isolation & Protection

  • Isolation Voltage: 500 V AC RMS (channel to logic, channel to channel)
  • Dielectric Strength: 2.2 kV AC for 60 seconds
  • Surge Protection: 1 kV per IEC 61000-4-5
  • ESD Protection: 8 kV contact, 15 kV air per IEC 61000-4-2
  • Overvoltage Category: III per IEC 60664-1

Environmental Ratings

  • Operating Temperature: -25°C to +70°C
  • Storage Temperature: -40°C to +85°C
  • Relative Humidity: 5% to 95% non-condensing
  • Vibration Resistance: 5-150 Hz, 2.0 G (operational)
  • Shock Resistance: 30 G, 11 ms half-sine
  • Ingress Protection: IP20 (requires enclosure)

Power Requirements

  • Logic Supply: 5 VDC ±5%, 120 mA maximum
  • Field Supply: 24-48 VDC, 100 mA (module consumption)
  • Total Module Power: ≤ 6 W maximum (all channels active)
  • Inrush Current: < 2 A for 10 ms

Mechanical Specifications

  • Module Dimensions: 110 × 75 × 35 mm (H × W × D)
  • Weight: 220 grams
  • Mounting: DIN rail TS35/7.5 or TS35/15
  • Terminal Type: Removable spring-cage terminals
  • Wire Range: 0.2-2.5 mm² (AWG 24-14)
  • Terminal Torque: 0.4-0.6 Nm

Compliance & Approvals

  • Safety Standards: IEC 61508, IEC 61511, ISO 13849-1
  • EMC: EN 61326-1 (industrial), FCC Part 15 Class A
  • Certifications: UL 508, CSA C22.2 No. 142, CE marked
  • Marine Approvals: DNV-GL, ABS (pending)
  • Hazardous Area: ATEX Zone 2, Class I Div 2

Applications

  • Safety shutdown solenoids and valves
  • Emergency stop circuits
  • Fire suppression system actuators
  • Process interlock final elements
  • Critical machine safety controls
  • Alarm and annunciation systems

System Integration

  • Compatible Controllers: Honeywell Safety Manager SC, Experion HS
  • Configuration Software: Safety Builder 4.0 or higher
  • Bus Interface: Safety-rated fieldbus protocol
  • Hot Swap Capable: Yes, with automatic configuration
  • Mean Time To Repair (MTTR): < 15 minutes
  • Preventivi rapidi: Ricevi rapidamente prezzi e disponibilità dal nostro team di assistenza clienti dedicato.
  • Consegna: Spedizioni rapide, trasporto merci e internazionali disponibili in tutto il mondo.
  • Garanzia: NexAuto offre una garanzia di 12 mesi su tutte le parti acquistate da noi, oltre a qualsiasi copertura del produttore.
  • Resi: Politica di reso di 30 giorni per parti difettose o non corrispondenti, per garantirti tranquillità.
  • Pagamento: Opzioni flessibili tra cui principali carte di credito, PayPal e bonifici bancari.
  • Calibrazione personalizzata: Fornisci le tue specifiche e ci occuperemo del resto con precisione.
Visualizza dettagli completi