MOXA EDS-2016-ML-MM-ST: Unmanaged Ethernet Switch with 14 Copper and 2 Fiber Ports

Key Technical Specifications

  • Brand: MOXA
  • Model: EDS-2016-ML-MM-ST
  • Category: Unmanaged industrial Ethernet switch
  • Copper Ports: 14 x 10/100BaseT(X) with RJ45 connectors
  • Fiber Ports: 2 x 100BaseFX multi-mode with ST connectors
  • Ethernet Standards: IEEE 802.3, 802.3u, 802.3x flow control, 802.1p Class of Service
  • Processing Type: Store and Forward
  • MAC Table Size: 8 K entries
  • Packet Buffer Size: 2 Mbits
  • DIP Switch Configuration: QoS, broadcast storm protection, port break alarm
  • Alarm Contact: Relay output, 1 A @ 24 VDC current carrying capacity
  • Input Voltage: 12/24/48 VDC with redundant dual inputs
  • Operating Voltage: 9.6 to 60 VDC
  • Input Current: 0.152 A @ 24 VDC
  • Power Connection: 1 removable 6-contact terminal block
  • Overload Current Protection: Supported
  • Reverse Polarity Protection: Supported
  • Housing: Metal, IP30 rated
  • Dimensions: 58 x 135 x 95 mm (2.28 x 5.31 x 3.74 in)
  • Weight: 648 g (1.43 lb)
  • Installation: DIN-rail mounting; wall mounting with optional kit
  • Operating Temperature: -10 to 60°C (14 to 140°F)
  • Storage Temperature: -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity: 5 to 95% (non-condensing)
  • EMI/EMC: EN 55032/35, EN 61000-6-2/-6-4, CISPR 32, FCC Part 15B Class A
  • EMS Immunity: ESD contact 6 kV / air 8 kV; RS 20 V/m; EFT power 2 kV / signal 2 kV; Surge power 2 kV / signal 2 kV; CS 10 V; PFMF
  • Hazardous Locations: Class I Division 2, ATEX, IECEx
  • Railway: EN 50121-4
  • Traffic Control: NEMA TS2
  • Maritime: DNV, LR, ABS, NK
  • Shock/Vibration/Freefall: IEC 60068-2-27, IEC 60068-2-6, IEC 60068-2-32
  • MTBF: 2,070,826 hours (Telcordia/Bellcore, GB standards)
  • Safety: UL 61010-2-201; EN 62368-1 (LVD)

Installation Guide

  • Mount the switch on a standard DIN rail for fast deployment in control cabinets.
  • Use the optional wall-mounting kit for panel or surface installation.
  • Connect the removable 6-contact terminal block to dual 12/24/48 VDC power sources.
  • Verify the operating voltage stays within 9.6 to 60 VDC during operation.
  • Wire the relay alarm contact to monitor port break events at 1 A @ 24 VDC.
  • Set QoS, broadcast storm protection, and port break alarm using the DIP switches.
  • Keep ambient temperature within -10 to 60°C and humidity at 5 to 95% non-condensing.

Package Contents

  • 1 x EDS-2016-ML-MM-ST switch
  • 1 x quick installation guide
  • 1 x warranty card

Shipping and Support

  • We ship orders within 5 days of confirmation.
  • We use FedEx, UPS, and DHL for international delivery.
  • We accept returns within 30 days of receipt.
  • All units are brand new and original from the manufacturer.
  • Stock is available for immediate order processing.

FAQ

  • Q: How many copper and fiber ports does the EDS-2016-ML-MM-ST offer?
    A: It provides 14 x 10/100BaseT(X) copper ports and 2 x 100BaseFX multi-mode ST fiber ports.
  • Q: Does the switch support redundant power inputs?
    A: Yes, it accepts dual 12/24/48 VDC inputs and operates within 9.6 to 60 VDC.
  • Q: What is the operating temperature range?
    A: The EDS-2016-ML-MM-ST operates from -10 to 60°C (14 to 140°F).
  • Q: What are the MAC table and packet buffer sizes?
    A: The switch offers an 8 K MAC table and a 2 Mbits packet buffer.
  • Q: Which industrial certifications does this model carry?
    A: It meets Class I Division 2, ATEX, IECEx, EN 50121-4 railway, NEMA TS2, and DNV/LR/ABS/NK maritime standards.
  • Q: Can I monitor port failures?
    A: Yes, the port break alarm and relay output (1 A @ 24 VDC) support failure monitoring.
  • Q: How do I configure QoS and storm protection?
    A: Use the DIP switches on the panel to enable or disable these functions.
  • Q: What is the MTBF of this product?
    A: The MTBF is 2,070,826 hours based on Telcordia (Bellcore) and GB standards.
  • Q: What is the warranty and return policy?
    A: We offer a 30-day return window; all units are new and original with stock available.
  • Quick Quotes: Receive pricing and availability fast from our dedicated customer service team.
  • Delivery: Expedited, freight, and international shipping available worldwide.
  • Warranty: NexAuto offers a 12-month warranty on all parts purchased from us, in addition to any manufacturer coverage.
  • Returns: 30-day return policy for defective or mismatched parts, ensuring peace of mind.
  • Payment: Flexible options including major credit cards, PayPal, and bank transfers.
  • Custom Calibration: Provide your specifications, and we’ll handle the rest with precision.
View Product Details