LV-N11MN Keyence LV-N Series Laser Sensor Amplifier Cable Type
Bulk Orders & Fast Shipping
Instant 10% Discount On Winter Banks Credit/Debit Cards EMI and CreditCard
Fast & Reliable Worldwide Shipping – Ready to Dispatch from Stock
- Fast shipping
- Return Policy
- Lowest Price
- Help Center 24/7
-
Vendor:
Keyence
-
Type:
Expansion Unit
- Tags Expansion unit
About the Product
LV-N11MN Keyence LV-N Series Digital Laser Sensor Amplifier (Cable Type Main Unit)
Technical Specifications
- Brand: Keyence
- Model: LV-N11MN
- Series: LV-N series
- Product type: Digital laser sensor amplifier, main unit
- Cable/connector: Cable type
- Output selection: LIGHT-ON / DARK-ON, switch-selectable
- Control outputs: 2 outputs (NPN open collector)
- External input: 1 input
- Monitor output: Available (analog)
- Response time: 80 µs (HIGH SPEED) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA)
- Timer function: OFF / OFF-delay / ON-delay / One-shot, 1 ms to 9,999 ms, ±10% maximum error
- Unit expansion: Up to 17 units total (2-output type counts as 2 units)
- Interference prevention: 0 to 4 units, depending on mode and sensor head
- Supply voltage: 24 VDC nominal (operating 10 to 30 VDC, ripple P-P 10% maximum)
- Power consumption: 830 mW maximum at 30 V; 30 mA at 24 V
- Output rating: NPN open collector 30 V, residual voltage 1 V or less, 100 mA maximum per output
- Protection circuit: Reverse polarity, over-current, surge absorber
- Operating temperature: -20 to +55 °C (no freezing; derating applies with multiple units)
- Relative humidity: 35 to 85 % RH (no condensation)
- Vibration resistance: 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each X, Y, Z direction
- Shock resistance: 500 m/s², 3 times in each X, Y, Z direction
- Dimensions (H×W×D): 32.6 × 9.8 × 78.7 mm
- Weight: Approx. 75 g
- Case material: Polycarbonate
- Cable material: PVC
- Communication: No built-in ports or protocols; network support via NU series units
- Protection rating: Not available
Performance and Environmental Durability
- The LV-N11MN provides six selectable response modes to balance speed and stability.
- HIGH SPEED mode reaches 80 µs for high-throughput detection tasks.
- Two control outputs and an analog monitor output support flexible inspection logic and setup checks.
- The amplifier tolerates -20 to +55 °C and 35 to 85 % RH without condensation.
- Vibration and shock ratings support reliable use on moving machinery and production equipment.
- Interference prevention limits cross-talk between 0 and 4 units, depending on mode and head.
- Reverse polarity, over-current, and surge absorber circuits protect the amplifier during wiring faults.
Installation Guide
- Mount the unit on a DIN rail or panel with the 32.6 × 9.8 × 78.7 mm housing.
- Route the cable carefully and secure it to avoid strain on the amplifier terminals.
- Wire the 24 VDC supply within the 10 to 30 VDC operating range.
- Select LIGHT-ON or DARK-ON with the switch to match your detection logic.
- Set the timer from 1 ms to 9,999 ms when your process needs delay or one-shot output.
- Chain expansion units up to 17 total units and check interference prevention settings.
- Keep multiple units within the derating limits for ambient temperature.
Package Contents
- 1 × Keyence LV-N11MN digital laser sensor amplifier (cable type main unit)
- 1 × Installation manual
Shipping
- We ship orders within 5 business days after payment confirmation.
- We use FedEx, UPS, and DHL for international delivery.
- We provide tracking information once your parcel leaves our warehouse.
FAQ
-
Q: Is the LV-N11MN new and original?
A: Yes. We supply brand-new original units, and we keep stock on hand for fast order fulfillment. -
Q: How fast do you ship?
A: We dispatch within 5 days, and we use common carriers such as DHL, FedEx, and UPS. -
Q: Can I return the product?
A: Yes. We accept returns within 30 days under our standard return policy. -
Q: What response time does the LV-N11MN support?
A: It offers 80 µs, 250 µs, 500 µs, 1 ms, 4 ms, and 16 ms modes. -
Q: Does this amplifier include a monitor output?
A: Yes. It provides an analog monitor output for setup and diagnostics. -
Q: How many outputs does this main unit have?
A: It has two control outputs and one external input. -
Q: How many units can I connect in one expansion chain?
A: You can connect up to 17 units total, and a 2-output type counts as 2 units. -
Q: What is the supply voltage range?
A: The nominal supply is 24 VDC, with an operating range of 10 to 30 VDC. -
Q: Can I use it in a network system?
A: Yes. You can add NU series network units for network communication, since the amplifier has no built-in ports.
Quick Quotes & Info
- Quick Quotes: Receive pricing and availability fast from our dedicated customer service team.
- Delivery: Expedited, freight, and international shipping available worldwide.
- Warranty: NexAuto offers a 12-month warranty on all parts purchased from us, in addition to any manufacturer coverage.
- Returns: 30-day return policy for defective or mismatched parts, ensuring peace of mind.
- Payment: Flexible options including major credit cards, PayPal, and bank transfers.
- Custom Calibration: Provide your specifications, and we’ll handle the rest with precision.

Industrial Electrical Solutions
Comprehensive Automation Equipment for Every Facility
PLCs, HMIs, Servo Drives, Sensors, and Cables for reliable operations.
BENTLEY NEVADA
Condition Monitoring Solutions
Proximity probes, sensors, and monitoring systems to protect critical machinery.
ALLEN-BRADLEY
Industrial Automation Components
High-quality PLCs, HMIs, and I/O modules for reliable control systems.
HONEYWELL
Controllers, I/O & Interface Modules
New parts to support DCS platforms and PLC installations.
Blog posts
-
Industrial Control Brands: 2026 DCS and PLC Selection Guide
Compare five industrial control brands for 2026. Get DCS and PLC selection advice, specs, and...
-
MTL Intrinsic Safety Loop No-Output Faults: Troubleshooting Guide
Diagnose MTL intrinsic safety loop no-output faults. Check power, wiring, grounding, and cable parameters fast.
-
Bently 3500 Alarms: Causes and Field Handling Guide
Bently 3500 alarm causes, transducer checks, and API 670 handling methods for reliability teams.