LV-N12CP Keyence Digital Laser Sensor Amplifier – 1-Output M8
Bulk Orders & Fast Shipping
Instant 10% Discount On Winter Banks Credit/Debit Cards EMI and CreditCard
Fast & Reliable Worldwide Shipping – Ready to Dispatch from Stock
- Fast shipping
- Return Policy
- Lowest Price
- Help Center 24/7
-
Vendor:
Keyence
-
Type:
Expansion Unit
- Tags Expansion unit
About the Product
LV-N12CP Keyence Digital Laser Sensor Amplifier — M8 Expansion Unit Overview
Key Technical Specifications
- Brand: Keyence
- Model: LV-N12CP
- Series: LV-N series
- Product type: Digital laser sensor amplifier
- Unit type: Expansion unit
- Connector: M8 connector type
- Output logic: LIGHT-ON / DARK-ON, switch-selectable
- Control outputs: 1 PNP open collector output
- External input: 1 input channel
- Response time: 80 µs (HIGH SPEED), 250 µs (FINE), 500 µs (TURBO), 1 ms (SUPER), 4 ms (ULTRA), 16 ms (MEGA)
- Timer function: OFF, OFF-delay, ON-delay, or One-shot; 1 ms to 9,999 ms with ±10% maximum error
- Monitor output: None
- Expansion capacity: Up to 17 units total; a 2-output type counts as 2 units
- Interference prevention: 0 to 4 units, depending on mode and sensor head
Electrical Ratings
- Supply voltage: 24 VDC nominal; operating range 10 to 30 VDC with 10% maximum ripple
- Power consumption: 830 mW maximum at 30 V; 30 mA at 24 V
- Output type: PNP open collector
- Output rating: 30 V maximum; residual voltage 1.2 V or less at ≤10 mA and 2.2 V or less at 10–100 mA
- Current capacity: 100 mA maximum per output
- Protection circuits: Reverse polarity, over-current, and surge absorber
- Communication: No built-in port or protocol; add an NU series network unit for network compatibility
Environmental Tolerance and Interference Resistance
- Operating temperature: -20 to +55 °C, no freezing; derating applies when you mount multiple units
- Relative humidity: 35 to 85% RH, no condensation
- Protection rating: Not available for this model
- Vibration resistance: 10 to 55 Hz at 1.5 mm double amplitude, 2 hours in each of the X, Y, and Z directions
- Shock resistance: 500 m/s², 3 times in each of the X, Y, and Z directions
- Interference control: The amplifier limits cross-talk between 0 and 4 neighboring units, depending on mode and sensor head
Physical Details
- Dimensions (H × W × D): 32.6 × 9.8 × 78.7 mm
- Weight: Approximately 20 g
- Case material: Polycarbonate
- Cable material: PVC
- Lifecycle status: Active; Keyence confirms production status on the official product page (last verified September 2026)
Installation Guide
- Pair the expansion unit with a main amplifier, then connect both units through the side connector.
- Mount each unit on a DIN rail or bracket, and leave space for heat dissipation in stacked setups.
- Connect the M8 connector firmly and route the cable away from motors and inverters to reduce noise.
- Wire the 24 VDC supply with correct polarity, then confirm the ripple stays within the 10% limit.
- Select LIGHT-ON or DARK-ON with the switch, and set the timer mode and value for your application.
- Keep the total expansion at 17 units or fewer, and count each 2-output unit as two.
- Verify the residual voltage at your load current, and never exceed 100 mA per output.
Package Contents
- 1 × Keyence LV-N12CP digital laser sensor amplifier expansion unit, M8 type
- 1 × Protective packaging for safe transport
- Documentation as supplied by the manufacturer
Shipping Options
- We ship worldwide through FedEx, UPS, and DHL.
- We dispatch in-stock orders within 5 days.
FAQ
-
Q: What is the difference between the LV-N12CP and a main unit?
A: This model is an expansion unit with 1 output, and it needs a main amplifier to form a working system. -
Q: What is the response time of the LV-N12CP?
A: The fastest mode reaches 80 µs, and you can select slower modes up to 16 ms for stable readings. -
Q: Does this amplifier accept PNP or NPN sensors?
A: The control output is PNP open collector, so plan your wiring around a PNP interface. -
Q: How many units can I connect together?
A: You can expand to 17 units total, and each 2-output unit counts as two units. -
Q: What supply voltage does the LV-N12CP need?
A: It runs on 24 VDC nominal and accepts 10 to 30 VDC with ripple within 10%. -
Q: Can I add network communication?
A: Yes, the amplifier has no built-in port, but an NU series network unit adds network compatibility. -
Q: What is the operating temperature range?
A: The unit works from -20 to +55 °C without freezing, and derating applies with multiple units. -
Q: Is the product new and in stock?
A: Yes, we offer brand-new original units, and we hold stock for immediate order processing. -
Q: What is your return policy?
A: We support returns within 30 days of delivery.
Quick Quotes & Info
- Quick Quotes: Receive pricing and availability fast from our dedicated customer service team.
- Delivery: Expedited, freight, and international shipping available worldwide.
- Warranty: NexAuto offers a 12-month warranty on all parts purchased from us, in addition to any manufacturer coverage.
- Returns: 30-day return policy for defective or mismatched parts, ensuring peace of mind.
- Payment: Flexible options including major credit cards, PayPal, and bank transfers.
- Custom Calibration: Provide your specifications, and we’ll handle the rest with precision.

Industrial Electrical Solutions
Comprehensive Automation Equipment for Every Facility
PLCs, HMIs, Servo Drives, Sensors, and Cables for reliable operations.
BENTLEY NEVADA
Condition Monitoring Solutions
Proximity probes, sensors, and monitoring systems to protect critical machinery.
ALLEN-BRADLEY
Industrial Automation Components
High-quality PLCs, HMIs, and I/O modules for reliable control systems.
HONEYWELL
Controllers, I/O & Interface Modules
New parts to support DCS platforms and PLC installations.
Blog posts
-
Industrial Control Brands: 2026 DCS and PLC Selection Guide
Compare five industrial control brands for 2026. Get DCS and PLC selection advice, specs, and...
-
MTL Intrinsic Safety Loop No-Output Faults: Troubleshooting Guide
Diagnose MTL intrinsic safety loop no-output faults. Check power, wiring, grounding, and cable parameters fast.
-
Bently 3500 Alarms: Causes and Field Handling Guide
Bently 3500 alarm causes, transducer checks, and API 670 handling methods for reliability teams.