S30A-6111CP SICK Safety Laser Scanner S3000
Bulk Orders & Fast Shipping
Instant 10% Discount On Winter Banks Credit/Debit Cards EMI and CreditCard
Fast & Reliable Worldwide Shipping – Ready to Dispatch from Stock
- Fast shipping
- Return Policy
- Lowest Price
- Help Center 24/7
-
Vendor:
SICK
-
Type:
Safety Laser Scanner
- Tags Safety laser scanner
About the Product
SICK S30A-6111CP Safety Laser Scanner – S3000 PROFINET IO Advanced
Technical Specifications
- Brand: SICK
- Model: S30A-6111CP
- Series: S3000 PROFINET IO Advanced
- Type: Safety Laser Scanner, sensor without system plug
- Application: Indoor
- Protective Field Range: 5.5 m
- Warning Field Range: 49 m (20 m at 20 % reflectivity)
- Distance Measuring Range: 49 m
- Scanning Angle: 190°
- Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm (configurable)
- Angular Resolution: 0.5°, 0.25° (depending on range and resolution)
- Response Time: 60 ms
- Protective Field Supplement: 100 mm
- Supply Voltage: 24 V DC (16.8 V DC to 28.8 V DC)
- Power Consumption: ≤ 0.8 A
- Housing Material: Aluminum die cast, RAL 1021 yellow
- Front Screen: Polycarbonate with scratch-resistant coating
- Dimensions (W x H x D): 155 mm x 185 mm x 160 mm
- Weight: 3.3 kg
Safety-Related Parameters
- Type: Type 3 (IEC 61496)
- Safety Integrity Level: SIL 2 (IEC 61508)
- Category: Category 3 (EN ISO 13849)
- Performance Level: PL d (EN ISO 13849)
- PFHD: 8.0 × 10⁻⁸
- Mission Time (TM): 20 years (EN ISO 13849)
- Safe State on Fault: Safety-related data is logic 0
- Protection Class: III (VDE 0106, EN 60950)
Environmental and Laser Data
- Enclosure Rating: IP65 (EN 60529)
- Ambient Operating Temperature: –10 °C to +50 °C
- Storage Temperature: –25 °C to +50 °C
- Vibration Resistance: IEC 60068-2-6, IEC 60068-2-64, IEC 61496-3, Class 5M1
- Shock Resistance: IEC 60068-2-27, IEC 61496-3, Class 5M1
- Continuous Shock: 50 m/s², 11 ms and 100 m/s², 16 ms
- Light Type: Pulsed laser diode, wavelength 905 nm
- Laser Class: Class 1 (IEC 60825-1, 21 CFR 1040.10/1040.11)
- Detectable Remission Factor: 1.8 % to > 1,000 %, reflectors
Network and Interface Features
- The integrated PROFINET IO device includes a 2-port real-time switch per PROFINET V2.2.
- A PROFIsafe profile provides 6-octet input and 6-octet output per IEC 61784-3-3 V2.4.
- Bus connection uses copper conductor with 2 female RJ-45 push-pull connectors.
- Configuration and diagnostics run through an RS-232 interface at up to 38.4 kBaud.
- Cycle times include 4, 8, 16, and 32 ms options.
- The switch supports auto-negotiation, auto-crossover (MDIX), auto-polarity, and 100Base-TX.
- GSDML files follow GSDML specification V2.25 and Conformance Class B.
Functions
- Restart interlock and multiple sampling support safe machine restart control.
- Monitoring case switching and simultaneous monitoring handle up to 2 protective fields.
- Dual field sets with 4 field sets and 8 fields cover complex protection layouts.
- Static protective field switching and contour-as-reference improve field adaptation.
- Integrated configuration memory speeds up device replacement.
- Measured data output via RS-422 supports diagnostics.
- Multiple samplings range from 2 to 16 and automatic reset delay ranges from 120 ms to 4,920 ms.
Installation Guide
- Mount the aluminum die-cast housing on a rigid indoor surface within the network cabinet area.
- Connect the two RJ-45 push-pull connectors to the PROFINET network and the controller.
- Provide a 24 V DC supply within the 16.8 V to 28.8 V range and keep current below 0.8 A.
- Load the GSDML file into the controller and assign the PROFIsafe address.
- Configure resolution, field sets, and monitoring cases through the RS-232 interface.
- Verify the IP65 seal and the scratch-resistant front screen after mounting.
Packing List
- 1 × SICK S30A-6111CP Safety Laser Scanner (sensor without system plug)
- 1 × Protective packaging
- 1 × Quick start documentation
Shipping and Support
- We ship worldwide via FedEx, UPS, and DHL.
- We dispatch in-stock items within 5 business days after order confirmation.
- We support returns within 30 days under our standard return policy.
- All units are brand new and original.
FAQ
-
Q: Does the S30A-6111CP include a system plug?
A: No. This model ships as a sensor without a system plug. You operate it only in a network with a corresponding controller. -
Q: What is the difference between the protective field and the warning field range?
A: The protective field range is 5.5 m. The warning field range reaches 49 m, or 20 m at 20 % reflectivity. -
Q: Which safety level does the scanner achieve?
A: It meets Type 3 (IEC 61496), SIL 2 (IEC 61508), Category 3, and PL d (EN ISO 13849). -
Q: How many protective fields can it monitor at the same time?
A: The device monitors up to 2 protective fields simultaneously. -
Q: What is the response time?
A: The response time is 60 ms. -
Q: Which network protocol does the scanner use?
A: It uses PROFINET IO with PROFIsafe and includes a 2-port real-time switch. -
Q: What are the ambient temperature limits?
A: The operating range is –10 °C to +50 °C. The storage range is –25 °C to +50 °C. -
Q: Is the front screen protected against scratches?
A: Yes. The polycarbonate front screen carries an outside scratch-resistant coating.
© 2026 NexAuto Technology Limited. All rights reserved.
Original Source: https://www.nex-auto.com/
Contact: sales@nex-auto.com
Phone: +86 153 9242 9628
Quick Quotes & Info
- Quick Quotes: Receive pricing and availability fast from our dedicated customer service team.
- Delivery: Expedited, freight, and international shipping available worldwide.
- Warranty: NexAuto offers a 12-month warranty on all parts purchased from us, in addition to any manufacturer coverage.
- Returns: 30-day return policy for defective or mismatched parts, ensuring peace of mind.
- Payment: Flexible options including major credit cards, PayPal, and bank transfers.
- Custom Calibration: Provide your specifications, and we’ll handle the rest with precision.

Industrial Electrical Solutions
Comprehensive Automation Equipment for Every Facility
PLCs, HMIs, Servo Drives, Sensors, and Cables for reliable operations.
BENTLEY NEVADA
Condition Monitoring Solutions
Proximity probes, sensors, and monitoring systems to protect critical machinery.
ALLEN-BRADLEY
Industrial Automation Components
High-quality PLCs, HMIs, and I/O modules for reliable control systems.
HONEYWELL
Controllers, I/O & Interface Modules
New parts to support DCS platforms and PLC installations.
Blog posts
-
DCS Vibration Monitoring for Oil & Gas Reliability
Integrate Bently Nevada vibration monitoring with DCS for oil and gas reliability. API 670 compliance,...
-
Chemical DCS Selection and Safe Operation Guide 2026
Practical 2026 guide to chemical DCS selection, redundancy, SIL integration and OT cybersecurity.
-
Unified PLC-DCS Control Platforms Boost Factory Efficiency
Unified PLC-DCS Control Platforms Raise OEE, Cut Downtime And Lift Factory Output.
















